Extended level gauges variable lenght with min level electrical signal and max temperature electrical signal
Material: transparent polycarbonate tube, Polyamide PA 66 black end caps. External aluminum guard. Customizable lenght.
Max working temperature: 80°C (176 F).
Max temperature electrical sensor: incorporated into the zinc plated M12 bolt with DIN swivel connector.
Options: max temperature electrical sensor calibrated at 60°C (140 F) o 70°C (158 F); electrical contact normally open (NO) or electrical contact normally closed (NC).
Operation features XLV-SL-ST-NO: in addition to the visual inspection, the floating elements closes the electrical circuit when it reaches the pre-set minimum level; the temperature sensor closes the electrical circuit once the pre-set max temperature is reached.
Operation features XLV-SL-ST-NC: in addition to the visual inspection, the floating elements closes the electrical circuit when it reaches the pre-set minimum level; the temperature sensor opens the electrical circuit once the pre-set max temperature is reached.
Avoid contact with alcohol based solutions and antifreeze fluids at high temperature.